GRP Armoured Rodent Proof Loose Tube Blue Nylon Jacket Fibre Optic Cable – OM3/OM4

SKU: GMX-XX

$0.00

(ex. GST)

5000 in stock

GRP Armoured Rodent Proof Loose Tube Blue Nylon Jacket Fibre Optic Cable – OM3/OM4

*** Please call (03) 9761 7925 for pricing ***

 

The RapidConnect® G-Series GRP Armoured Fibre Optic Cable provides combined rodent and termite protection within a non-metallic loose tube cable construction.

The cable uses GRP rods as the rodent-protection layer, while a Blue Nylon inner jacket provides termite protection. A durable Black PE outer jacket completes the external protective system.

Because the GRP armour contains no conductive metal, the G-Series remains an all-dielectric cable. Therefore, it provides strong physical protection without introducing steel armour, corrosion risk, or the electrical considerations commonly associated with metallic armoured cable.

Available from fibreSales, the G-Series suits demanding underground telecommunications, industrial, utility, mining, transport, campus and infrastructure networks where biological attack could threaten long-term fibre reliability.

RapidConnect G-Series at a Glance

  • GRP rod armour for rodent protection
  • Blue Nylon inner jacket for termite protection
  • Black PE external jacket
  • Non-metallic armour
  • All-dielectric construction
  • No steel armour
  • Corrosion-resistant armour system
  • Dry water-blocking technology
  • Loose tube fibre construction
  • Suitable for underground ducts and conduits
  • Singlemode and multimode fibre options
  • Multiple fibre counts available
  • Designed for demanding infrastructure environments
  • Manufactured to suit project requirements

Why Choose GRP Armoured Fibre Optic Cable?

Rodents and termites create different threats to underground fibre cable.

Rodents can physically gnaw through conventional cable jackets and damage buffer tubes or fibres. Termites create a separate biological risk and may attack polymeric materials in underground environments.

The RapidConnect G-Series addresses both risks through a layered protection system.

GRP rods provide the physical rodent barrier.

Blue Nylon provides the termite barrier.

Black PE provides the external environmental and mechanical jacket.

This combination gives network designers a purpose-built protected cable rather than relying on one jacket material to manage every threat.

How the G-Series Cable Is Constructed

From outside to inside, the RapidConnect G-Series uses:

  1. Black PE outer jacket
  2. GRP armour rods
  3. Blue Nylon termite-protection jacket
  4. Internal loose tube fibre optic cable core

Each layer performs a different function.

This layered design allows the cable to address external mechanical exposure, rodents, termites, moisture and fibre protection within one coordinated cable structure.

Black PE Outer Jacket

The Black PE jacket forms the external surface of the G-Series.

It protects the GRP armour and internal cable components during:

  • Transportation
  • Handling
  • Cable hauling
  • Installation
  • Long-term outdoor service

Polyethylene offers a useful combination of toughness, flexibility and moisture resistance for outdoor telecommunications cable.

However, the Black PE jacket does not provide the primary rodent or termite protection.

Instead, the specialised GRP and Blue Nylon layers sit beneath the PE sheath.

GRP Rod Armour for Rodent Protection

The G-Series uses Glass Reinforced Plastic rods beneath the outer PE jacket.

These rods form a hard physical barrier around the protected inner cable.

If a rodent damages the Black PE sheath, the GRP armour sits between the animal and the inner fibre cable.

Therefore, the protection does not depend only on the outer jacket remaining untouched.

The GRP rods provide:

  • Physical rodent resistance
  • Circumferential protection
  • Mechanical reinforcement
  • Non-metallic armour
  • Electrical isolation
  • Corrosion resistance

This makes GRP particularly useful where a project requires armoured protection but the designer wants to avoid metallic cable components.

Blue Nylon Termite Protection

Beneath the GRP armour, the G-Series incorporates a Blue Nylon inner jacket.

This layer provides dedicated termite protection around the internal loose tube cable.

The construction creates two distinct biological protection systems:

  • GRP rods for rodents
  • Blue Nylon for termites

The contrasting blue jacket also helps technicians identify the protected inner cable during cable preparation.

Non-Metallic and All-Dielectric Construction

Traditional armoured fibre cable often uses steel tape, corrugated steel or steel wire.

These constructions can provide excellent mechanical protection, but they also introduce metal into the cable.

Depending on the installation, metallic armour may introduce additional considerations involving:

  • Earthing
  • Bonding
  • Electrical continuity
  • Lightning exposure
  • Induced voltage
  • Earth potential differences
  • Corrosion
  • Separation from electrical services

RapidConnect G-Series uses non-metallic GRP armour instead.

As a result, the cable retains an all-dielectric construction while still providing a substantial physical protective layer.

Engineering Decision

Choose G-Series when you need rodent and termite protection but want to avoid conductive metallic armour.

This can prove particularly valuable around electrical infrastructure, industrial environments, utilities and other locations where electrical isolation forms part of the cable-selection process.

Corrosion-Resistant Armour

GRP does not rust like steel.

Therefore, the G-Series can provide an advantage in wet, humid or corrosive environments where damaged metallic armour could degrade over time.

Potential environments include:

  • Underground conduit systems
  • Wet pits
  • Coastal infrastructure
  • Industrial facilities
  • Water and wastewater infrastructure
  • Mining operations
  • Agricultural environments
  • Regional telecommunications networks

The Black PE jacket still protects the cable externally. However, the GRP armour itself does not suffer from conventional steel corrosion.

Dry Water-Blocking Technology

Underground ducts and pits do not always remain dry.

Groundwater, condensation, flooding and damaged seals can introduce moisture into cable pathways.

RapidConnect G-Series uses dry water-blocking technology to help restrict longitudinal water movement if moisture reaches the internal cable structure.

Dry water blocking can also make cable preparation cleaner than traditional fully gel-flooded cable designs.

Benefits include:

  • Reduced longitudinal water migration
  • Cleaner cable preparation
  • Less gel removal
  • Easier termination
  • Improved site cleanliness
  • Additional protection following localised jacket damage

However, installers should still seal cable ends and enclosure entries correctly.

Water blocking supports moisture management; it does not replace good installation practice.

Loose Tube Fibre Construction

The G-Series uses loose tube technology to protect the optical fibres from external mechanical and environmental effects.

In a loose tube cable, the fibres sit within protective buffer tubes rather than directly against the surrounding cable layers.

This helps isolate the fibres from:

  • Temperature changes
  • Pulling loads
  • Mechanical movement
  • External pressure
  • Installation stress

Loose tube construction also supports a range of fibre counts and Singlemode or multimode configurations.

Where to Use RapidConnect G-Series

RapidConnect G-Series suits infrastructure where rodents, termites or both present a credible long-term risk.

Typical applications include:

  • Telecommunications networks
  • Underground duct systems
  • Conduit networks
  • Industrial facilities
  • Mining and resources
  • Utilities
  • Transport infrastructure
  • Rail networks
  • Water infrastructure
  • Wastewater networks
  • Campus fibre links
  • Inter-building connections
  • Regional telecommunications
  • Agricultural sites
  • Critical infrastructure

Telecommunications Infrastructure

Long telecommunications routes can pass through pits, conduits and locations that are difficult to access after installation.

A single damaged cable may affect many network services.

Therefore, physical biological protection can provide significant value on backbone and inter-building routes where repairs would require civil work, fault location and emergency restoration.

Industrial Networks

Industrial facilities can provide ideal pathways for rodents through service corridors, plant rooms and protected infrastructure.

At the same time, fibre networks may support:

  • Process control
  • Monitoring
  • Safety systems
  • Communications
  • Automation
  • Security

The G-Series combines physical protection with non-conductive armour, making it well suited to demanding industrial environments.

Mining and Resources

Mining sites often combine large geographic areas, demanding environments and difficult maintenance access.

Fibre links may support operational technology, network communications, monitoring and production systems.

Where biological attack presents a risk, G-Series provides a non-metallic alternative to steel-armoured cable.

Utilities and Electrical Environments

GRP armour can provide particular advantages near electrical infrastructure.

Because GRP does not conduct electricity, the G-Series avoids introducing a metallic armour path into the fibre route.

Potential applications include:

  • Electrical substations
  • Utility networks
  • Industrial plants
  • Renewable energy infrastructure
  • Power-related facilities

The complete installation must still meet applicable standards and project requirements.

Campus and Inter-Building Fibre

Schools, hospitals, universities, commercial campuses and government sites often connect buildings with underground fibre links.

Landscaped areas, pits and older conduits may expose these networks to rodents or termites.

Therefore, the G-Series provides an option where cable-level biological protection forms part of the network design.

GRP Armoured vs Steel Armoured Fibre Cable

GRP and steel armour solve similar problems in different ways.

FeatureGRP ArmourSteel Armour
Rodent protectionYesYes
MetallicNoYes
ConductiveNoYes
Corrosion riskLowPossible
Bonding considerationsReducedMay apply
Earthing considerationsReducedMay apply
Electrical isolationExcellentLower
WeightOften lowerOften higher
FlexibilityOften betterOften stiffer

Steel armour remains appropriate for many installations.

However, GRP can provide a better solution where the project needs mechanical protection without introducing conductive metal.

G-Series vs Standard Loose Tube Fibre Cable

A standard loose tube cable can provide excellent outdoor performance.

However, it may not include dedicated rodent or termite protection.

The G-Series adds these specialised layers:

  • GRP rod armour
  • Blue Nylon termite barrier
  • Black PE outer jacket

Therefore, choose standard loose tube cable when biological protection does not drive the specification.

Choose G-Series when rodent and termite exposure justify a more protected construction.

G-Series vs Termite-Protected Cable

Some outdoor cables provide termite protection without rodent armour.

G-Series goes further by combining both protection types.

Choose a standard termite-protected cable when termite resistance is the primary concern.

Choose RapidConnect G-Series when the project requires:

Rodent protection + termite protection + non-metallic armour.

Selecting the Right G-Series Configuration

Before ordering, consider the complete installation.

Biological Risk

Determine whether the route faces:

  • Rodents
  • Termites
  • Both

Previous cable damage, pest activity and site conditions can help identify the actual exposure.

Fibre Type

Select the correct fibre category for the network.

Options may include:

  • Singlemode
  • Multimode

Your transmission distance, active equipment and future network requirements should guide the selection.

Fibre Count

Allow for:

  • Current services
  • Redundancy
  • Spare fibres
  • Future expansion
  • Network growth

Installing additional fibre capacity during the original project usually costs less than adding another cable later.

Installation Pathway

Confirm whether the cable will run through:

  • Conduits
  • Ducts
  • Pits
  • Service tunnels
  • Industrial pathways
  • Other underground infrastructure

Do not assume one cable construction suits every underground installation method.

Mechanical Requirements

Review:

  • Pulling tension
  • Bend radius
  • Crush resistance
  • Impact exposure
  • Cable diameter
  • Hauling method

The final values should come from the exact supplied configuration.

Environmental Conditions

Consider:

  • Moisture
  • Flooding
  • Chemicals
  • Temperature
  • UV exposure
  • Corrosive environments
  • Electrical surroundings

Installation Considerations

Correct installation protects every layer of the cable.

Before installation, confirm:

  • Cable route
  • Pathway dimensions
  • Pulling method
  • Maximum tensile load
  • Minimum bend radius
  • Drum orientation
  • Cable preparation method
  • Enclosure compatibility
  • Gland requirements
  • Testing requirements

During cable preparation, technicians should take particular care when removing the Black PE outer jacket and GRP rods.

The Blue Nylon layer underneath provides termite protection, so installers should avoid damaging it unnecessarily.

Fibre Testing After Installation

Professional fibre installation requires optical testing before commissioning.

Depending on the project, testing may include:

  • Continuity
  • Insertion loss
  • OTDR testing
  • Splice-loss assessment
  • Link-length verification
  • End-face inspection
  • Polarity confirmation

fibreSales supplies OTDRs, Fusion Splicers, Fibre Cleaning Products and Fibre Inspection Microscopes for professional installation and commissioning work.

Why Biological Protection Matters

Rodent or termite damage can turn a relatively small cable breach into a major infrastructure problem.

Once the outer jacket becomes damaged, the network may face:

  • Moisture ingress
  • Buffer tube damage
  • Fibre stress
  • Increased attenuation
  • Fibre breakage
  • Service outages
  • Fault-finding costs
  • Excavation
  • Cable replacement
  • Emergency splicing

For remote or difficult-to-access routes, these costs can far exceed the initial difference between standard cable and a purpose-built protected cable.

Whole-of-Life Value

Cable price represents only one part of an underground fibre project.

Civil work, labour, pits, conduits, splicing, testing and network downtime often cost substantially more than the cable itself.

Therefore, choosing cable only on initial metre price can create a false economy.

For routes with identified biological risks, the G-Series can provide valuable long-term protection through:

  • Rodent resistance
  • Termite resistance
  • Corrosion-resistant armour
  • Dry water blocking
  • Electrical isolation
  • Loose tube fibre protection

Why Buy RapidConnect G-Series from fibreSales?

fibreSales supplies fibre optic cable and installation products for Australian telecommunications, industrial and infrastructure networks.

When requesting pricing, provide:

  • Fibre type
  • Fibre count
  • Required cable length
  • Installation method
  • Rodent exposure
  • Termite exposure
  • Pathway type
  • Drum requirements
  • Delivery location
  • Project timing

This information helps us identify the most appropriate G-Series configuration for your project.

Frequently Asked Questions

What is GRP Armoured Fibre Optic Cable?

GRP Armoured Fibre Optic Cable uses Glass Reinforced Plastic rods to create a non-metallic protective barrier around the fibre cable core.

What protects the G-Series against rodents?

The GRP rods form the dedicated rodent-protection layer.

What protects the cable against termites?

The Blue Nylon inner jacket provides termite protection.

What is the G-Series construction order?

From outside to inside:

Black PE outer jacket → GRP rods → Blue Nylon jacket → loose tube cable core.

Is the Blue Nylon the outer jacket?

No. The Black PE jacket forms the external surface of the finished cable.

Is GRP metallic?

No. GRP is a non-metallic composite material.

Is G-Series an all-dielectric cable?

Yes. The non-metallic GRP armour allows the cable to remain all-dielectric.

Does GRP armour need earthing?

GRP itself does not require earthing in the way metallic armour may. However, the complete installation must still comply with applicable project and electrical requirements.

Does GRP rust?

No. GRP does not rust like steel.

Does G-Series include termite protection?

Yes. The Blue Nylon jacket provides dedicated termite protection.

Does G-Series include water blocking?

Yes. The cable uses dry water-blocking technology.

Is water blocking the same as waterproofing?

No. Water blocking helps limit longitudinal moisture movement inside the cable. Installers still need to seal cable ends, glands and enclosures correctly.

Can the G-Series be installed underground?

The G-Series suits underground infrastructure such as suitable duct and conduit networks. Confirm the exact installation method against the supplied cable configuration.

Is it suitable for direct burial?

Do not assume direct-burial suitability solely from the presence of GRP armour and a PE jacket. Confirm the selected construction specifically for the intended installation.

Is Singlemode available?

Yes. G-Series configurations can support suitable Singlemode fibre options.

Is Multimode available?

Yes. Multimode configurations may also be available depending on project requirements.

What fibre counts are available?

Multiple fibre counts can be manufactured. Confirm your required configuration with fibreSales when requesting a quote.

Is GRP lighter than steel armour?

GRP can provide a smaller, lighter and more flexible construction than many steel-armoured alternatives. Final weight depends on the selected cable configuration.

Why use GRP rather than steel?

GRP provides physical armour without introducing conductive metal, corrosion risk or the same bonding and earthing considerations associated with steel.

Does armour remove the need for careful installation?

No. Installers must still follow the specified pulling tension, bend radius, crush limits and cable-preparation requirements.

Order RapidConnect G-Series GRP Armoured Fibre Cable

Protect your underground fibre infrastructure from both rodent and termite damage with RapidConnect G-Series.

For quotation, provide fibreSales with your:

Fibre type | Fibre count | Cable length | Installation method | Rodent risk | Termite risk | Drum requirements | Delivery location

Contact fibreSales to discuss the correct G-Series configuration for your project.

Conclusion

RapidConnect G-Series provides a specialised solution for infrastructure where rodents, termites and environmental exposure could compromise standard outdoor fibre cable.

Its layered construction combines a Black PE outer jacket, non-metallic GRP rod armour, Blue Nylon termite protection and a loose tube fibre core.

As a result, the cable delivers strong biological protection while retaining the advantages of an all-dielectric, corrosion-resistant fibre cable design.

For more fibre optic solutions, technical resources, and installation products, visit www.fibresales.com.au.