Green SC Angled Duplex Singlemode Adaptor with Ceramic Alignment Sleeves- 12 pack

SKU: SCDAI-125

$15.50

(ex. GST)

1000 in stock

Green SC Angled Duplex Singlemode Adaptor with Ceramic Alignment Sleeves- 12 pack

 

The Green SC Angled Duplex Singlemode Adaptor provides precise alignment between compatible angled-polish SC connectors in Singlemode fibre networks.

High-precision ceramic alignment sleeves maintain accurate ferrule positioning for stable and repeatable optical connections. Meanwhile, the duplex housing accommodates two SC fibre connections within one convenient assembly.

Its distinctive green housing identifies the adaptor as the angled-polish SC configuration, helping technicians distinguish it from blue straight-polish Singlemode connectivity.

Supplied by fibreSales in packs of 12, these adaptors suit telecommunications networks, fibre backbones, access networks, equipment rooms and other Singlemode optical infrastructure.

Green SC Angled Adaptor at a Glance

  • SC Duplex configuration
  • Angled-polish Singlemode application
  • Green housing
  • Ceramic alignment sleeves
  • High-precision fibre alignment
  • Typical insertion loss ≤0.2 dB
  • Designed for low back reflection
  • Excellent interchangeability
  • Excellent repeatability
  • Good temperature characteristics
  • Meets UL94-V0 flammability requirements
  • Supplied in packs of 12

What Is a Green SC Angled Duplex Adaptor?

A Green SC Angled Duplex Adaptor provides the physical interface required to connect compatible angled-polish SC Singlemode connectors.

Precision ceramic sleeves inside the adaptor position the mating ferrules in accurate alignment. As a result, optical signals can pass efficiently between the connected fibres.

Duplex construction combines two SC connection points within one housing, providing an organised interface for fibre pairs.

Designed for Angled-Polish SC Connectivity

Angled-polish fibre connectors use an angled ferrule end face to reduce reflected optical power at the connection.

This characteristic makes angled-polish connectivity particularly useful in optical systems where return loss and back reflection require careful control.

Common applications include:

  • Telecommunications networks
  • Fibre access networks
  • Passive optical networks
  • Optical fibre CAT
    • V
    • Singlemode backbone infrastructure
    • Fibre distribution systems
    • Equipment rooms
    • Telecommunications cabinets

    The complete fibre channel should use the connector polish specified for the network design.

    Engineering Decision

    Choose the Green SC Angled Duplex Singlemode Adaptor when your installation uses compatible angled-polish SC Singlemode connectors and requires ceramic alignment sleeves.

    Never mate angled-polish and straight-polish connector end faces together. Confirm the connector polish throughout the optical path before making the connection.

    Green Housing for Angled-Polish Identification

    Colour coding helps technicians identify connector configurations inside fibre panels and distribution equipment.

    The green housing provides visual identification for angled-polish SC connectivity. Consequently, installers can distinguish these adaptors from blue Singlemode SC adaptors intended for straight-polish connections.

    However, colour should support rather than replace proper network documentation and connector inspection.

    Ceramic Alignment Sleeves

    Singlemode fibre connectivity requires precise ferrule alignment.

    For this reason, the adaptor uses ceramic alignment sleeves to position compatible SC connector ferrules accurately.

    Key characteristics include:

    • High-precision alignment
    • Excellent dimensional stability
    • Consistent connector positioning
    • Excellent repeatability
    • Excellent interchangeability
    • Reliable optical connectivity

    Accurate mechanical alignment helps minimise unnecessary loss at the connection point.

    Why Angled-Polish Connections Reduce Back Reflection

    A conventional flat or slightly curved fibre interface can reflect a small amount of optical power back toward the transmitting equipment.

    Angled polishing changes the geometry of the connector interface. Rather than directing reflected light straight back along the fibre core, the angled end face helps direct reflections away from the optical path.

    This makes angled-polish connectivity useful where low back reflection is important to system performance.

    Typical Insertion Loss ≤0.2 dB

    Supplied specifications state a typical insertion loss of ≤0.2 dB.

    Each connection contributes to the overall optical loss budget. Therefore, network designers should consider adaptors alongside connectors, patch leads, pigtails, splices and equipment interfaces.

    Maintaining low connection loss helps preserve available optical power across the complete Singlemode link.

    SC Duplex Connectivity

    SC connectors use a push-pull interface widely found throughout fibre optic telecommunications infrastructure.

    Combining two SC connections within one duplex housing keeps associated fibre connections organised. This arrangement also simplifies patch-panel layouts where the network requires paired optical connections.

    Typical installation locations include:

    • Fibre patch panels
    • Rack-mount fibre enclosures
    • Wall-mount enclosures
    • Telecommunications cabinets
    • Fibre distribution frames
    • Equipment racks
    • Access-network infrastructure

    For fibre distribution projects, explore fibreSales Fibre Optic Enclosures.

    High-Precision Ceramic Alignment

    Reliable optical coupling depends on accurate positioning of the mating fibre ferrules.

    When compatible connectors enter opposite sides of the adaptor, the ceramic sleeve maintains their physical alignment. In turn, precise positioning supports consistent optical performance.

    The sleeve itself does not alter the optical signal; instead, it provides the mechanical accuracy required at the connection interface.

    Excellent Repeatability and Interchangeability

    Fibre connections may be disconnected during equipment changes, maintenance, troubleshooting or network upgrades.

    Excellent repeatability helps maintain consistent alignment after compatible connectors are reinserted. Furthermore, good interchangeability supports straightforward integration throughout compatible SC infrastructure.

    Technicians should inspect and clean every connection as required before remating the connectors.

    Product Specifications

    SpecificationDetails
    ProductGreen SC Angled Duplex Singlemode Adaptor
    Connector TypeSC
    ConfigurationDuplex
    Fibre ApplicationSinglemode
    Connector Polish ApplicationAngled
    Housing ColourGreen
    Alignment SleeveCeramic
    Typical Insertion Loss≤0.2 dB
    Back ReflectionLow
    Flammability RequirementUL94-V0
    AlignmentHigh Precision
    InterchangeabilityExcellent
    RepeatabilityExcellent
    Temperature CharacteristicGood
    Pack Quantity12 Adaptors

    Standards and Compliance

    Supplied product information identifies compliance with requirements including:

    • ANSI
    • TIA/EIA
    • NTT
    • JIS
    • UL94-V0 flammability requirements

    Where a project requires a particular standard, revision or performance specification, confirm the exact compliance requirements before installation.

    Typical Applications

    Green SC Angled Duplex Singlemode Adaptors can support connectivity across:

    • Telecommunications networks
    • Access networks
    • Passive optical networks
    • Optical fibre CATV
    • Singlemode fibre backbones
    • Fibre distribution systems
    • Telecommunications equipment
    • Fibre patch panels
    • Equipment terminations
    • Testing equipment
    • Industrial optical networks

    Final suitability depends on the complete optical system and its specified connector interface.

    Angled vs Straight-Polish SC Connectivity

    Although both versions use the SC connector format, their connector end faces differ.

    FeatureGreen SC AngledBlue SC Singlemode
    Fibre TypeSinglemodeSinglemode
    Housing IdentificationGreenBlue
    Connector FormatSC DuplexSC Duplex
    Polish ApplicationAngledStraight-polish configuration
    Alignment SleeveCeramicCeramic
    Typical Insertion Loss≤0.2 dB≤0.2 dB
    Back ReflectionDesigned for lower reflectionDifferent return-loss characteristics

    Connector polish compatibility matters more than housing colour alone.

    Do not mate an angled-polish connector directly with an incompatible straight-polish connector. Mismatched end-face geometry can create poor physical contact, increased loss and potentially damage the connector surfaces.

    Singlemode Connectivity for Fibre Patch Panels

    SC Duplex Adaptors commonly provide accessible connection points within fibre patch panels and optical distribution enclosures.

    One interface can connect to the terminated fibre inside the enclosure, while the opposite side accepts the corresponding patch lead. Consequently, equipment-side connections can change without disturbing the fixed fibre infrastructure.

    Using green adaptors also helps technicians identify angled-polish connection points within the panel.

    Pack of 12 Green SC Adaptors

    Each pack contains 12 Green SC Angled Duplex Singlemode Adaptors.

    The pack quantity suits:

    • New fibre installations
    • Patch-panel builds
    • Access-network deployments
    • Telecommunications projects
    • Fibre network expansions
    • Equipment-room upgrades
    • Maintenance stock
    • Replacement requirements

    Keeping spare adaptors available can also reduce delays when a damaged component requires replacement.

    Inspect and Clean Before Connection

    Contamination can increase optical loss and back reflection even when the adaptor provides precise mechanical alignment.

    Dust, oils and microscopic debris on a connector end face may interfere with the optical interface. Consequently, technicians should inspect and clean connectors whenever required before making the connection.

    A professional process includes:

    1. Inspect the connector end face.
    2. Clean it when contamination is present.
    3. Re-inspect after cleaning.
    4. Check the mating interface where appropriate.
    5. Connect only after confirming cleanliness.

    fibreSales supplies Fibre Cleaning Products and Fibre Inspection Microscopes for professional fibre maintenance.

    Choosing the Correct SC Fibre Adaptor

    Several details should be checked before ordering.

    Confirm the Fibre Type

    This adaptor is intended for Singlemode fibre applications.

    Check the Connector Format

    The product accepts compatible SC connectors.

    Verify the Polish Configuration

    This green adaptor is intended for angled-polish SC connectivity.

    Select the Correct Configuration

    Duplex construction accommodates two SC fibre connections within one housing.

    Confirm the Alignment Sleeve

    High-precision ceramic alignment sleeves provide ferrule positioning.

    Checking all five requirements helps prevent incompatible fibre connections.

    Related Fibre Products

    Complete your Singlemode fibre installation with:

    Why Buy Green SC Angled Adaptors from fibreSales?

    fibreSales supplies fibre connectivity, installation, cleaning and testing products for Australian telecommunications and network infrastructure.

    These Green SC Duplex Adaptors combine Singlemode connectivity, angled-polish compatibility, ceramic alignment sleeves and typical insertion loss ≤0.2 dB.

    Additionally, the 12-pack format provides a practical quantity for new installations, expansions and maintenance stock.

    Together, these features make the adaptors a reliable connection solution for compatible angled-polish SC Singlemode networks.

    Frequently Asked Questions

    What is a Green SC Angled Duplex Adaptor?

    It is a Singlemode fibre optic adaptor designed to align and connect compatible angled-polish SC connectors.

    Is this adaptor Singlemode?

    Yes. The product is intended for Singlemode fibre applications.

    Why is the adaptor green?

    Green provides visual identification for the angled-polish SC configuration.

    What type of alignment sleeve does it use?

    Each adaptor uses a ceramic alignment sleeve for high-precision ferrule positioning.

    Is the adaptor simplex or duplex?

    This product uses an SC Duplex configuration.

    How many fibre connections does one adaptor accommodate?

    Each duplex housing accommodates two SC fibre connections.

    What is the typical insertion loss?

    Supplied specifications state ≤0.2 dB typical insertion loss.

    Why use an angled-polish connection?

    The angled connector end face helps reduce optical back reflection compared with non-angled connector interfaces.

    Can I connect an angled-polish SC connector to a straight-polish SC connector?

    No. Connector polish types should match. Mating incompatible angled and straight-polish connector end faces can cause excessive loss and potentially damage the connector surfaces.

    How many adaptors are included?

    Each pack contains 12 adaptors.

    Can these adaptors be installed in fibre patch panels?

    Yes, provided the panel accepts the corresponding SC Duplex adaptor format.

    Should connectors be cleaned before installation?

    Yes. Inspect and clean fibre connector end faces as required before making a connection.

    Order Green SC Angled Duplex Singlemode Adaptors – 12 Pack

    Build or maintain your Singlemode fibre network with the Green SC Angled Duplex Singlemode Adaptor with Ceramic Alignment Sleeves – 12 Pack from fibreSales.

    Combining high-precision ceramic alignment, angled-polish connectivity and typical insertion loss ≤0.2 dB, these adaptors provide a reliable SC connection interface for compatible Singlemode fibre infrastructure.

    Order your 12-pack online from fibreSales.

    Conclusion

    The Green SC Angled Duplex Singlemode Adaptor provides precise connectivity for compatible angled-polish SC connectors.

    Ceramic alignment sleeves maintain accurate ferrule positioning, while the angled-polish interface supports applications where low optical back reflection is important. Furthermore, the duplex housing accommodates two SC connections within one organised assembly.

    Supplied in packs of 12, these adaptors suit telecommunications networks, access infrastructure, fibre distribution systems, patch-panel installations and ongoing maintenance.

    For more fibre optic solutions, technical resources, and installation products, visit www.fibresales.com.au.

    Continue Learning

s

 

 

Attachments

FileFile size
Fibre Optic Adaptors Brochure4 MB

Attachments

FileFile size
Fibre Optic Adaptors Brochure4 MB